ACT Black 2 meter LSZH U/UTP CAT6 datacenter slimline patch cable snagless with RJ45 connectors
Item No.
DC9902
- Cable length: 2 m
- Full copper 28AWG wires, 50µ gold RJ-45 contacts
- Outer diameter jacket of only 3.8mm to improve air flow in cabinet
- Snagless boots
- For connecting active equipment
- Specifications comply to international standards
- Cables are 100% tested
- 5 Year warranty
CAT6 U/UTP slimline datacenter ethernet cables are smaller in diameter (3.8mm vs 5.9mm) than regular CAT 6 patch cords. The bending radius is lower in comparison with regular patchcords. All this results in a better airflow in the server rack/network cabinet.
Although ISO/IEC and the TIA standards describe the use of patch cords between 22 and 26 AWG, it is possible to use 28 AWG patch cables. This results in a higher attenuation, particularly at higher frequencies.
ACT advises a maximum bundle size of 24 cables in PoE applications. In this case the temperature of the cables, that are delivering PoE deployments, will not increase. The standard, ANSI TSB-184-A, limits the maximum temperature increasement, to less than 15 degrees Celsius above the ambient temperature, for the center cable in a bundle.
Although ISO/IEC and the TIA standards describe the use of patch cords between 22 and 26 AWG, it is possible to use 28 AWG patch cables. This results in a higher attenuation, particularly at higher frequencies.
ACT advises a maximum bundle size of 24 cables in PoE applications. In this case the temperature of the cables, that are delivering PoE deployments, will not increase. The standard, ANSI TSB-184-A, limits the maximum temperature increasement, to less than 15 degrees Celsius above the ambient temperature, for the center cable in a bundle.
Description
- Cable length: 2 m
- Full copper 28AWG wires, 50µ gold RJ-45 contacts
- Outer diameter jacket of only 3.8mm to improve air flow in cabinet
- Snagless boots
- For connecting active equipment
- Specifications comply to international standards
- Cables are 100% tested
- 5 Year warranty
CAT6 U/UTP slimline datacenter ethernet cables are smaller in diameter (3.8mm vs 5.9mm) than regular CAT 6 patch cords. The bending radius is lower in comparison with regular patchcords. All this results in a better airflow in the server rack/network cabinet.
Although ISO/IEC and the TIA standards describe the use of patch cords between 22 and 26 AWG, it is possible to use 28 AWG patch cables. This results in a higher attenuation, particularly at higher frequencies.
ACT advises a maximum bundle size of 24 cables in PoE applications. In this case the temperature of the cables, that are delivering PoE deployments, will not increase. The standard, ANSI TSB-184-A, limits the maximum temperature increasement, to less than 15 degrees Celsius above the ambient temperature, for the center cable in a bundle.
Although ISO/IEC and the TIA standards describe the use of patch cords between 22 and 26 AWG, it is possible to use 28 AWG patch cables. This results in a higher attenuation, particularly at higher frequencies.
ACT advises a maximum bundle size of 24 cables in PoE applications. In this case the temperature of the cables, that are delivering PoE deployments, will not increase. The standard, ANSI TSB-184-A, limits the maximum temperature increasement, to less than 15 degrees Celsius above the ambient temperature, for the center cable in a bundle.
Specifications
Brand | ACT |
Product category | CAT6 patch cables U/UTP |
Cable length | 2 m |
Connector type | RJ45 |
Connector A | RJ45 male (x1) |
Connector B | RJ45 male (x1) |
Contact plating | Gold plated |
Connector contact plating | Gold plated |
Mating cycles | 750 |
Shielding type | U/UTP |
Category | CAT6 |
Conductor material | Copper |
Wire gauge | 28 AWG |
Outer jacket | LSZH |
Bandwidth | 250 MHz |
Cable colour | Black |
Colour number | RAL 9011 |
Min. working temperature | -20 °C |
Brand item no. | DC9902 |
EAN code | 8716065404746 |