ACT CAT6 U/UTP solid twisted pair cable, PVC, AWG 24, CPR: B2ca, 500 m

Item No. XS6002
Reel 500 mtr
  • This cable is conform CPR Euroclass: B2ca, s2, d1
  • Full copper conductors and comply with the ANSI/TIA-568-C2 performance requirements.
  • With pair Splitter
  • Specifications comply to international standards
This cable is conform CPR Euroclass: B2ca, s2, d1
DoP number: 1175349 / XS6002-CPR

Permanent twisted pair cabling also known as vertical or horizontal cabling is used above ceilings and in cable ducts and connects to the wall outlet at the work space. From the outlet patchcables are used to connect to the notebook, docking station or pc.

Permanent cabling is typically installed by installers and because of that you can also see the term installation cable used.

Permanent cabling contains more copper then patchcables / patchcords and because of this is excellent for bridging longer distances. Because of the usage of more copper in a solid wire permanent cabling is also know as solid cabling. Solid / permanent cables are less flexible then patchcables, patchcables are also known as zipcords.
Out of stock Low stock In stock
Out of stock Low stock In stock
No stock or not enough stock available?
Please contact our sales department for actual delivery dates
This product cannot be ordered at the moment.
Description
Reel 500 mtr
  • This cable is conform CPR Euroclass: B2ca, s2, d1
  • Full copper conductors and comply with the ANSI/TIA-568-C2 performance requirements.
  • With pair Splitter
  • Specifications comply to international standards
This cable is conform CPR Euroclass: B2ca, s2, d1
DoP number: 1175349 / XS6002-CPR

Permanent twisted pair cabling also known as vertical or horizontal cabling is used above ceilings and in cable ducts and connects to the wall outlet at the work space. From the outlet patchcables are used to connect to the notebook, docking station or pc.

Permanent cabling is typically installed by installers and because of that you can also see the term installation cable used.

Permanent cabling contains more copper then patchcables / patchcords and because of this is excellent for bridging longer distances. Because of the usage of more copper in a solid wire permanent cabling is also know as solid cabling. Solid / permanent cables are less flexible then patchcables, patchcables are also known as zipcords.
Specifications
Brand ACT
Product category CAT6 Twisted pair cable
Length per packaging 500 m
Shielding type U/UTP
Category CAT6
Conductor material Copper
Conductor type Solid
Wire gauge 24 AWG
Outer jacket PVC
Outer diameter 6.2 mm
Impedance 100 Ω
Bandwidth 250 MHz
Cable colour Grey
Colour number RAL 7047
Min. working temperature -15 °C
Max.working temperature 60 °C
CPR compatible Yes
CPR Euroclass Bca
Approval UL
Brand item no. XS6002
EAN code 8716065410983